Maximum wastewater discharge

The maximum wastewater discharge for grease separator design can be determined in three ways. The largest wastewater discharge determined is taken into account for the design.

Symbol or abbreviation:

Qs

Usual unit:

l/s

Table 1. Determination method for maximum wastewater discharge
FormulaExplanation
-The maximum wastewater discharge is measured.
  • Qs: maximum wastewater discharge in l/s
  • m: Serial number of the fixture according to DIN EN 1825-2 Table A.1 or according to DIN EN 1825-2 Table A.2
  • n: Number of fixtures and fittings
  • qi: Maximum wastewater discharge of the fixture in l/s in accordance with DIN EN 1825-2 Table A.1 and DIN EN 1825-2 Table A.2
  • Z i: Simultaneity factor in accordance with DIN EN 1825-2 Table A.1 and DIN EN 1825-2 Table A.2
  • Qs: Maximum wastewater discharge in l/s
  • V: Average daily wastewater volume according to DIN EN 1825-2 Table A.3
  • F: unitless impact load factor depending on the operating mode
  • t: average daily operating time in hours