Circulation (DHW design options)
Calculation parameters for hot water and cold water circulation are specified in the Circulation area under Calculation.
The following calculation parameters can be specified in the Circulation area on the PWC-C and PWC-H tabs:
- Specification of the maximum permissible difference between hot water and circulation temperature (ΔϑTE) at a DHW heater in K
- Specification of the maximum permissible flow velocity for circulation pipes < DN20 (vmax) in m/s
- Specification of the mean pressure drop (Rm) of the circulation pipes including the individual resistance losses in hPa/m
- Minimum pressure loss in thermostatic circulation control valves (ΔpZRV,min) in hPa
- Use the Consider mixing factor checkbox to specify whether the design should take the mixing factor into account.
- Specifying the mixing factorNote:The value entered must be between 0 and 1.