Edit drinking water heater

In the ‘Drinking Water Heating’ dialogue box, you can adjust individual calculation properties for the KTS fresh water station and its installation dimensions.

Fresh Water Station section
  • From the ‘Product’ drop-down menu, select the desired product for the fresh water station.
    Note:
    If you have selected the ‘Calculating...’ option, a suitable product will be determined automatically.
  • In the ‘Maximum number’ drop-down menu, select the maximum number of KTS fresh water stations to be used.
    Note:
    You can only select the maximum number if you have selected ‘is being calculated... ’ under ‘Product ’.
  • In the ‘Minimum number’ drop-down menu, select the minimum number of KTS fresh water stations to be used.
    Note:
    You can only select the minimum number if you have selected ‘To be calculated... ’ under ‘Product ’.
  • In the ‘Permissible pressure drop ’ input field, enter the maximum permissible pressure drop at peak flow rate in accordance with DIN 1988-300.
  • From the ‘Electrical Conductivity’ drop-down menu , select the material of the plate heat exchanger to be used.
    Note:
    If the option < 500 CU is selected, the water quality must be checked to ensure it is suitable for a copper-brazed plate heat exchanger.
    Note:
    For further information on the application limits of the respective materials, click on the ‘ ’ button.
    Note:
    You can only select the material of the plate heat exchanger to be used if you have selected the entry ‘is being calculated...’ under ‘Product ’.
  • Tick the ‘BACnet connection’ checkbox if the fresh water stations are to be connected via BACnet.
Installation Dimensions section
  • By activating the Check installation dimensions checkbox, you can specify the installation surfaces for checking.
  • Enter the installation area in metres in the ‘Installation area length l’ input fieldTB.
  • Enter the installation area width bTB in the ‘Installation area width b’ input field in metres.
Confirm details
  • Exit the ‘Drinking Water Heating ’ dialogue box by clicking ‘OK’.